The Alice Night One is a portable, user-friendly device designed for monitoring sleep patterns and physiological data. It combines non-invasive sensors with wireless connectivity for seamless operation, offering both clinical and home-based sleep study solutions. Engineered for comfort and ease of use, the device is ideal for patients undergoing sleep analysis, providing accurate and reliable data collection. Its intuitive design ensures minimal disruption to the user’s natural sleep environment, making it a versatile tool for both healthcare professionals and individuals.
Overview of the Alice Night One
The Alice Night One is a portable physiological data recorder designed for both supervised hospital and unsupervised home environments. It automatically powers on when the effort belt is connected, ensuring a seamless setup process. The device is equipped with sensors to monitor various physiological parameters during sleep, providing comprehensive data collection. Its compact design and user-friendly interface make it ideal for patients undergoing sleep studies. The Alice Night One is intended to collect data on body position, respiratory effort, and other vital signs, aiding in accurate sleep analysis and diagnosis.
Key Features and Benefits
The Alice Night One offers a portable, user-friendly design with guided setup for easy application of sensors and connections. It features automatic power-on when the effort belt is connected, ensuring a seamless start. The device includes a user button for manual operation, providing flexibility. Its non-invasive sensors and wireless connectivity allow for uninterrupted monitoring, making it ideal for both home and clinical use. The Alice Night One is designed for comfort, minimizing sleep disruption, and provides accurate physiological data collection, enhancing sleep study outcomes and improving diagnostic accuracy;
System Requirements and Compatibility
The Alice Night One operates in both supervised and unsupervised environments, supporting a variety of power sources, including battery and external power options, ensuring versatility and reliability.
Operating Environment
The Alice Night One is designed for use in both supervised hospital settings and unsupervised home environments. It operates effectively in temperatures between 50°F and 95°F (10°C and 35°C) and humidity levels up to 80%. The device is lightweight and portable, making it suitable for various setups. It automatically powers on when the effort belt is connected, ensuring a streamlined experience. Manual activation is also possible via the user button, offering flexibility for different scenarios. The device’s robust design ensures reliable performance across diverse operating conditions.
Technical Specifications
The Alice Night One features a compact, lightweight design, weighing approximately 12 ounces, with dimensions of 4.5 x 3 x 1 inches. It includes a rechargeable lithium-ion battery, offering up to 24 hours of continuous use. The device supports wireless connectivity for data transfer and is compatible with both Windows and macOS systems. It incorporates sensors for respiratory effort, oxygen saturation, and body position, ensuring comprehensive data collection. The internal memory stores up to 24 hours of physiological data, and the device operates on a 12V DC power supply. It is designed for durability and ease of use in both clinical and home settings.
Installation and Setup
The Alice Night One device is easy to set up. Connect the effort belt, nasal cannula, and finger probe; The device powers on automatically when sensors are connected. Follow the guided setup instructions for proper sensor placement and configuration. Use the user button if manual activation is needed. Ensure all components are securely attached for accurate data collection. Refer to the user manual for detailed step-by-step guidance.
Unboxing and Initial Setup
Begin by carefully unboxing the Alice Night One device and its accessories, including the effort belt, nasal cannula, and finger oximeter. Inspect all components for damage. Place the device on a flat surface and connect the sensors according to the quick start guide. The effort belt should be buckled around your chest, with the red dots facing outward. Slide your finger into the oximeter, ensuring the wire runs along your hand. Connect the nasal cannula securely. Power on the device automatically by connecting the effort belt or press the user button. Follow the guided setup to synchronize sensors and prepare for use.
Connecting Sensors and Accessories
Connect the effort belt by buckling it around your chest, ensuring the red dots on the connectors face outward. Attach the nasal cannula securely to monitor breathing. Place the finger oximeter on your non-dominant hand, with the wire running along the top. Ensure all sensors are snug but comfortable. Connect each accessory to the Alice Night One device, following the guided setup prompts; Verify all connections are secure to prevent data loss during monitoring. Proper sensor placement is crucial for accurate physiological data collection during sleep studies.
Power Management and Battery Life
The Alice Night One device is designed for extended use, with a battery life that typically lasts throughout a full night of monitoring. To ensure optimal performance, charge the device fully before use using the provided USB cable. The device automatically powers on when the effort belt is connected, minimizing manual intervention. For extended sessions, keep the device charged to avoid interruptions. Proper power management ensures continuous data collection and reliable operation during sleep studies. Regularly cleaning the battery contacts and avoiding overcharging can extend the device’s longevity and maintain its efficiency over time.
Pre-Test Preparation
Ensure all sensors are correctly placed, and follow your normal bedtime routine. Put the device on about 30 minutes before sleep to allow it to acclimate.
Tips for a Successful Home Sleep Test
- Prepare all sensors and accessories beforehand to avoid delays.
- Follow your normal bedtime routine to maintain natural sleep patterns.
- Put the device on 30 minutes before sleep to allow it to acclimate.
- Ensure the effort belt is snug and the oximeter is on your non-dominant hand.
- Avoid consuming alcohol or caffeine, as they may disrupt sleep.
- Charge the device fully before starting the test.
- Keep the room quiet and at a comfortable temperature.
- Secure all sensors firmly to prevent disconnections during sleep.
Preparing the Device for Use
To prepare the Alice Night One for use, ensure all sensors are connected securely. The effort belt should be buckled snugly around your chest, with the red dots on the connectors facing outward. Attach the nasal cannula and finger oximeter, placing the oximeter on your non-dominant hand. Press and hold the user button to manually power on the device if needed. Check that all sensors are functioning properly before starting the test. The device will automatically begin recording when the effort belt is connected. Ensure all wires are securely fastened to avoid disconnections during sleep.
Device Operation
The Alice Night One automatically starts when the effort belt is connected or can be manually activated using the user button. It monitors and records sleep data, guiding you through setup with visual icons and lights. The device ensures a seamless experience, allowing you to focus on your sleep while it captures essential physiological information. Its intuitive design makes operation straightforward, even for first-time users. Follow the on-device prompts for a smooth testing process.
Understanding the Icons and Lights
The Alice Night One features four icons on the top: effort belt, nasal cannula, pulse oximeter, and user button. These icons light up to indicate status and guide operation. A solid light confirms proper connection, while blinking signals an issue. Yellow flashing lights paired with an alarm indicate sensor malfunctions. The user button, located on the front, allows manual control if needed. Icons and lights provide real-time feedback, ensuring smooth operation and troubleshooting. This visual system helps users understand device status and address any issues promptly for an uninterrupted testing experience.
Navigating the User Interface
The Alice Night One features a straightforward and intuitive user interface designed for easy navigation. The device includes a user button for manual control and guided setup to assist with sensor application. Icons on the top provide visual feedback, indicating sensor connections and device status. The interface is minimalist, with clear indicators for operation. Pressing and holding the user button powers the device on, while the guided setup ensures proper sensor placement. The interface is designed to be user-friendly, making it simple to operate during sleep testing without requiring advanced technical knowledge or complex adjustments.
Starting and Stopping the Test
To start the test, ensure all sensors are properly connected. The Alice Night One automatically powers on when the effort belt is connected. If manual start is preferred, press and hold the user button until the device confirms startup with a light indicator. To stop the test, press and hold the user button until the device confirms shutdown. The process is designed to be simple and intuitive, ensuring minimal disruption. The device may also automatically stop recording in the morning based on pre-set parameters or when the test duration is completed.
Monitoring and Sensors
The Alice Night One uses advanced sensors to monitor sleep patterns, including an effort belt, nasal cannula, and pulse oximeter. These sensors provide real-time physiological data, ensuring accurate sleep analysis.
Sensor Placement and Adjustment
Proper sensor placement is crucial for accurate data collection. The effort belt should be buckled around the chest, with red dots facing outward, and the nasal cannula should fit snugly. The pulse oximeter is placed on the non-dominant hand, with the wire running along the top. Adjust the sensors to ensure comfort and secure connection. Proper placement minimizes discomfort and ensures reliable physiological data recording during sleep studies. Follow the user manual for detailed guidance on positioning each sensor correctly for optimal performance and accurate results. This ensures a successful home sleep test experience. Always verify sensor placement before starting the test.
Types of Monitoring and Data Collection
The Alice Night One device monitors various physiological parameters, including respiratory effort, oxygen saturation, and body position. It collects data through sensors like the pulse oximeter, nasal cannula, and effort belt. The device records airflow, chest movement, and oxygen levels, storing data internally for later analysis. This comprehensive monitoring ensures detailed sleep study results, capturing essential information for diagnosing sleep disorders. The data collection process is automatic, providing accurate and reliable insights into sleep patterns and physiological changes during the night. Regular use enhances understanding of sleep health and supports effective treatment plans. Always ensure sensors are properly placed.
Troubleshooting
Common issues include sensor malfunctions or connectivity problems. Restart the device, check sensor connections, and ensure proper placement. Refer to the user manual for error codes and solutions.
Common Issues and Solutions
Common issues with the Alice Night One include sensor malfunctions or poor connectivity. If sensors fail to detect data, ensure they are properly connected and placed according to guidelines. If the device does not power on, press and hold the user button for 3 seconds. For error codes, consult the user manual or restart the device. If issues persist, contact customer support for assistance. Regularly updating software and cleaning sensors can prevent many problems. Always refer to the manual for detailed troubleshooting steps.
Sensor Malfunction and Error Codes
Sensor malfunctions may occur due to loose connections or improper placement. Check the effort belt, nasal cannula, and pulse oximeter for secure attachment. If the yellow light flashes, an error code appears on the screen. Common codes include E1 (low signal) or E2 (sensor disconnected). Restart the device or reattach sensors as needed. For unresolved issues, consult the user manual or contact support. Regular cleaning of sensors with a soft cloth prevents dirt-related errors. Always ensure sensors are properly calibrated for accurate data collection.
Maintenance and Support
Regularly clean the device with a soft cloth and avoid harsh chemicals. Store it in a dry place. For issues, contact Philips customer support for assistance.
Cleaning and Storing the Device
Regular cleaning ensures optimal performance and longevity. Use a soft, dry cloth to wipe the device and sensors. Avoid harsh chemicals or abrasive materials. For storage, place the Alice Night One in a protective case or pouch to prevent damage. Store in a cool, dry environment away from direct sunlight. Ensure all sensors and accessories are securely packed to avoid tangling or damage. Refer to the user manual for detailed cleaning and storage instructions to maintain the device’s functionality and extend its lifespan.
Contacting Customer Support
For assistance with the Alice Night One, contact Philips customer support via phone, email, or through their official website. Visit www.philips.com for contact details and downloadable resources. The support team is available to address technical issues, provide troubleshooting guidance, and answer operational questions. Ensure to have your device serial number ready for efficient service. Refer to the user manual for additional support options and regional contact information to resolve any queries promptly and effectively.